- Type
- MIDI Effect
- Author
- bcm70
- License
- AttributionNonCommercialShareAlike
- Live version
- 10.0.1
- Max version
- 8
- Downloads
- 423
- Updated
- 2018-05-27
Description
Device that allows control of the following per voice parameters on an EIV series sampler running EOS4.0 or above:
1. Preset selection
2. Preset Voice selection
3. Preset Global Volume
4. Voice Amplifier Volume, Amplifier Pan, Amplifier Depth and Submix
5. Voice Amp Envelope Attack Rates, Attack Level %s, Decay Rates, Decay Level %s, Release Rates and Release Level %s
6. Voice Filter Type, Cutoff Frequency and Resonance
7. Voice Filter Envelope Attack Rates, Attack Level %s, Decay Rates, Decay Level %s, Release Rates and Release Level %s
8. Voice LFO Rates, Shapes, Delays, Var %s, Sync, Lag 0 and Lag 1
9. Cord 0-17 Source, Destination and Amount %s.
10. FX A and FX B type selection.
Zip file contains two devices and a pdf of instructions on how to use setup the devices in Live and how to configure your sampler.
This is a work in progress and the intention is to add more functionality over time and merge these devices with the Emu Front Panel Control device I also have posted to the site into a single device.
Comments (21)
You're not in multi mode are you? What model sampler you using?
Unfortunately i can't test my script at the moment. Just moved house and on setting up my gear, the E5000 blew up as I powered it up. I suspect (hope) it's just the PSU, but haven't had a chance to look.
The other possibility is that my implementation doesn't work any more - they may have changed the way Sysex works in Max. The original setup with the SysMsg was required because you couldn't send and receive Sysex on the same channel in Live 10. That's been fixed.
So feel free to modify the script.
The other thing that could be causing you grief is your OS version. I have 4.7 on my sampler, so I've never tried it on anything but that.
comment: doesn't understand "int"
What is SysMsg.amxd needed for? It's not mentioned in the PDF?
newobj: live.banks: No such object
comment: doesn't understand "int" (when I double click it highlight the Depth which defaults to -96 db)
wav: PWM-1 never goes away. When is Live supposed to update the preset name?
Is maybe something wrong with my setup? I have two tracks, one with the external instrument and EMU control and another track with SysListener with Monitor set to In - Midi From is Channel 1 on the EMU. When I change the preset on the E-MU sampler, the Midi In signal blinks of the track with SysListener but nothing updates.
What would be a simple debug message I could add to the Max script to check if it receives a sysmessage at all?